Mp#0-
Had some issues with input 40 not reading because EOAT was not retracting brackets correctly. Kenny and I found bad solenoid valve and swapped it with a spare temporarily until we can get a replacement.
Numatics225-285B
24VDC 6.3 watts
Replacement Unit No.
#081SS400M000061
Mp#1-
Techs accidentally overtravelled the Z axis and couldn't get it to power back up. We ended up manually activating the brake on the X axis and moved it out of the mold area. It then allowed us to power it up and move it from the overtravelled condition.
Mp#2-
Finished wiring 24 common circuit into core switch receptacles. Only Mp#4 and #5 remain to be done as scheduling permits.
Began construction on another Corlogix box. I will check with MRO to see what parts are available and give Kenny a list for the remainder of items needed.
Have a great day!
No comments: