Wednesday, April 8, 2015

4.6.15 - Nissei control issues

MP#23-

We had a problem where somehow the upper range limit for setting the shot size got changed. We now presume that it may have been related to a low battery condition. The fix supposedly goes like this:

1. In manual operating mode > hold down the alarm reset button on the operator station (yellow).

2. While holding it down > manually retract the screw back until a prompt field appears on the controller screen. Follow its instructions.

This procedure has not been carried out as the priority of the machine has required it to run all night without interruption.

Additionally, we had an issue where one of our technicians inadvertently changed the dialog language from English over to Kanji writing. This was executed on the "shift>main data" page. Top right corner. To undo this event and return back to English, the language must be returned to bilingual or trilingual > then > go to the compile page and select English from the language field. Note: the language field may not be present initially and the process may have to be repeated with care.

The shift main data page is also where the units of measurement are located, in case someone changes from Fahrenheit to Centigrade.

For reference >According to Don Thornwald of Nissei North America, technical support:

"With barrel at oper. Temps. Hold alarm reset PB in and same time to screw backward with CS4 switch. Go back max. distance pump loading and hold there until message appears.

Release alarm PB & inject screw all the way fwd. then check SM range.

On compile screen, left side is language selection."
 
 
 
 

No comments:

Post a Comment